Difference between revisions of "Jamilah's Space"

From Green Garage Detroit
Jump to: navigation, search
(Green Garage Use of ??)
(Green Garage Labs)
Line 33: Line 33:
 
* [https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B9bEzr-Y2qtaYzg2NTNlMDAtNTYyYS00NmM1LThiNTQtMzk5MTYyOTVlZjgw&hl=en "Before Conditions" Thermal Inspection Report - 3/25/2011]
 
* [https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B9bEzr-Y2qtaYzg2NTNlMDAtNTYyYS00NmM1LThiNTQtMzk5MTYyOTVlZjgw&hl=en "Before Conditions" Thermal Inspection Report - 3/25/2011]
  
=== Green Garage Labs ===
+
=== Green Garage Labs Experiment #0001 ===
 
----
 
----
 
==== Sustainability Goals ====
 
==== Sustainability Goals ====
* The specific goals we're trying to achieve. This should be the performance outcomes.  
+
* Measure before and after wall painted to see magnitude of impact in application in Detroit to benchmark real results.  
* Strive to quantify if at all possible.
+
* Collect any lessons learned that might help others who may want to use the product.
* It doesn't describe how...just the outcomes.
+
* Collaborate with Urban Sustainable Library to document our findings.
  
==== Strategy and Conceptual Design ====
+
==== Strategies and Experiment Design ====
* Describe how we plan to achieve these goals
+
* Thermal image wall to be painted on cold day prior to painting.
* Explain why we chose this specific strategy and design (our rationale)
+
* Thermal image same wall on similar cold day after painting.
* Include pictures, drawings or videos(flickr)
+
* Use measurements to estimate energy savings achieved (snapshot for conditions on day measured).
 +
* Depending on results, may annualize findings (Linear regression/Bin data or energy modeling?).
 +
* Document on GG Labs Wiki.
  
 
===== Supporting science: =====
 
===== Supporting science: =====
 +
* [http://www.insuladd.com/testing/insuladdtestingoverview.html Insuladd Manufacturer's Testing]
 +
* Heat transfer measurement in actual operation; simulation to predict/estimate annual savings
 +
* Riley Tax/Landlord may compare future energy bills to previous years (normalized for weather, occupancy, hours of operation)
  
 
==== Proposed Materials / Suppliers ====
 
==== Proposed Materials / Suppliers ====
* Identify (via links and short description) the materials and suppliers we propose to use.
+
* [http://www.insuladd.com/index.html Insuladd - Thermal Barrier Paints & Additives - currently testing]
 
+
* [http://www.hytechsales.com/ceramics/ Hy-Tech Thermal Solutions - not tested]
==== Development Story ====
+
* [http://www.enerchecksystems.com/suprthrm.html Supertherm Insulating Paint - not tested]
The [[?? - Development Story]] page contains many images and videos documenting the process used at the Green Garage to design, build and operate our ?? system.
+
  
 
=== Related Internal Links ===
 
=== Related Internal Links ===

Revision as of 19:04, 5 April 2011

return to Living Building Design Studio

Laurie Jamilah 1.JPG

Riley's Tax Service


  • Small business operates January-April providing tax services
  • Jamilah Humphrey, owner, rents space in a building in Detroit on Fenkell near Southfield Freeway.
  • Jamilah has reported that the indoor space temperatures are uneven and uncomfortably cold near the East wall of the building. She would like to improve the thermal performance of the wall by applying paint mixed with an insulating (ceramic) additive. She was given a package of Insuladd by a friend involved in the building trade and plans to paint the wall with that. Laurie Catey, a professional engineer and commissioning authority, and Kirsten Lyons of the Green Garage are assisting Jamilah with her experiment.
  • Also known as: Sustainability Labs Experiment #1

Building Info


1100 sq. ft. space:

  • 3 outside walls (South, East, West)
  • Masonry (brick and block) walls w/interior drywalled stud walls
  • Built-up flat roof
  • 9'-6" suspended ceiling
  • Gas forced-air furnace heat from rooftop unit
  • Large plastic single pane inoperable windows on South and East sides
  • Large air leaks observed in ceiling tiles, receptacles, and around doors and windows

Site visit March 25, 2011


  • Laurie Catey and Kirsten Lyons measured and recorded with Jamilah Humphrey providing background and statement of problem
  • Outdoor temp. 32F (weather.com)
  • Indoor temp. 67.8F (back), 19% R.H. (Laurie Catey metered)
  • Front space temp. 67.5F, R.H. 18% (metered)
  • Storage room temp. (far back) 47-48F
  • Thermostat read 71F
  • Long east wall surface in back room measured 61-64F
  • Recorded "before" conditions using Flir thermal imaging camera
  • "Before Conditions" Thermal Inspection Report - 3/25/2011

Green Garage Labs Experiment #0001


Sustainability Goals

  • Measure before and after wall painted to see magnitude of impact in application in Detroit to benchmark real results.
  • Collect any lessons learned that might help others who may want to use the product.
  • Collaborate with Urban Sustainable Library to document our findings.

Strategies and Experiment Design

  • Thermal image wall to be painted on cold day prior to painting.
  • Thermal image same wall on similar cold day after painting.
  • Use measurements to estimate energy savings achieved (snapshot for conditions on day measured).
  • Depending on results, may annualize findings (Linear regression/Bin data or energy modeling?).
  • Document on GG Labs Wiki.
Supporting science:
  • Insuladd Manufacturer's Testing
  • Heat transfer measurement in actual operation; simulation to predict/estimate annual savings
  • Riley Tax/Landlord may compare future energy bills to previous years (normalized for weather, occupancy, hours of operation)

Proposed Materials / Suppliers

Related Internal Links

Resources


To Do's


  • After notified wall has been painted, take "after" thermal images on day with similar outside air conditions (approx. 32F and sunny).
  • Compare results to manufacturer's information.
  • Document and close out experiment.