Line 17: | Line 17: | ||
** Zone 1 = Historic Building = 30 people | ** Zone 1 = Historic Building = 30 people | ||
** Zone 2 = Addition = 10 people | ** Zone 2 = Addition = 10 people | ||
+ | * '''Hours of Operation''' | ||
+ | ** 8am - 6 pm |
Revision as of 11:18, 30 March 2009
- Building Size
- Zone 1 = Historic Building (8,721sf)
- Zone 2 = Addition (2,720sf)
- Building Volume
- Zone 1 = Historic Building Height - Assume 17ft
- Zone 2 = Addition (2,720sf)- Assume 15 ft
- Windows / Doors
- WWR of 27%
- U = .27
- Insulation
- Roof = R55
- Walls = R45
- Floor = R25
- Infiltration
- = 0.1
- People
- Zone 1 = Historic Building = 30 people
- Zone 2 = Addition = 10 people
- Hours of Operation
- 8am - 6 pm