Difference between revisions of "Green Garage - Current Design Assumptions"

From Green Garage Detroit
Jump to: navigation, search
Line 22: Line 22:
 
* '''Infiltration'''
 
* '''Infiltration'''
 
** = 0.1
 
** = 0.1
* '''People'''
+
* '''Use / People'''
** Zone 1 = Historic Building = 30 people
+
** Zone 1 = Historic Building = Office Space with 30 people
** Zone 2 = Addition = 10 people
+
** Zone 2 = Addition = Studio Workshops with 10 people
 
* '''Hours of Operation'''
 
* '''Hours of Operation'''
 
** 8am - 6 pm
 
** 8am - 6 pm

Revision as of 14:21, 30 March 2009

  • Location
  • Building Age
    • Zone 1 = Historic Building - built in 1920
    • Zone 2 = Addition - built in 1967
  • Building Size
    • Zone 1 = Historic Building (8,721sf)
    • Zone 2 = Addition (2,720sf)
  • Building Volume
    • Zone 1 = Historic Building Height - Assume it averages 17ft...actually a barrel roof with bow truss
    • Zone 2 = Addition (2,720sf)- Assume 15 ft ... flat roof
  • Windows / Doors
    • WWR of 27%
    • U = .27
  • Insulation
    • Roof = R55
    • Walls = R45
    • Floor = R25
  • Infiltration
    • = 0.1
  • Use / People
    • Zone 1 = Historic Building = Office Space with 30 people
    • Zone 2 = Addition = Studio Workshops with 10 people
  • Hours of Operation
    • 8am - 6 pm