EnviroSolids Building

From Green Garage Detroit
Revision as of 18:00, 17 May 2012 by Tom Brennan (Talk | contribs) (Building Recommendations (Burt))

Jump to: navigation, search

Building Recommendations (Burt)

  • Computer Model
    • Entire building
      • Allows you to evaluate any change / idea
      • Basis on all incentive programs
    • Walls
      • WUFI (catches vapor/condensation build up)
  • Strategy
    • Passive
      • reduce your demand...then meet the low demand
      • Work with the natural system
    • Prioritize...heat, cooling, lighting, hot water = 90% of energy
      • Insulate the envelope ... Building Science - Perfect Wall
        • Roof = 60R
        • Floor = 25R
        • Walls = 30R
      • Eliminate Thermal Bridges (focus on walls)
        • All connect points
          • Walls-to-Roof
          • Walls-to-Floor
          • Walls-to-walls
          • Window and door framing
          • Wall framing
      • Air Infiltration (focus on walls, windows and doors)
        • < 1 Air Exchange per hour
        • ALL building seams
          • Windows and Doors seals and framing
            • Walls-to-Roof
            • Walls-to-Floor
      • Windows
        • Window-to-wall ratio not > 27%
        • SHGC = .3 or below
        • Windows U = .27 or below
        • Eliminate Doorwalls
  • Materials
    • spray foam for all cracks
    • cfl bulbs inside and induction outside
    • aircrete for walls
    • mix insulation
  • Incentives
    • IRS = Efficient Buildings
    • DTE Yes
    • Smart Buildings - DEGC