Line 52: | Line 52: | ||
** Zone 2 = Addition (2,720sf) | ** Zone 2 = Addition (2,720sf) | ||
* '''Analysis''' | * '''Analysis''' | ||
− | # Solar Gain - use window shading to block solar gain | + | # Examine Solar Gain - use window shading to block solar gain |
− | # | + | # Examine heat from lighting - eliminate internal lighting |
− | + | # Examine heat from other internal sources - eliminate other sources | |
+ | # Try running simulation under "Free Run" which is the building without HVAC, ventilation, internal gains | ||
+ | * Refinements | ||
*** Wall sizes | *** Wall sizes | ||
*** WWF% using Laura's numbers | *** WWF% using Laura's numbers | ||
− | |||
− | |||
− | |||
* '''Outputs''' | * '''Outputs''' | ||
Revision as of 10:09, 14 April 2009
Versions of Energy-10 input / output that model our design process for the Green Garage
Contents
V1.0 - Existing
- Inputs
- Existing walls, floors, roof, windows (none)
- Existing heating system
- No Cooling
- Default lighting and other uses assuming office and warehouse uses
- Zone 1 = Historic Building (8,721sf)
- Zone 2 = Addition (2,720sf)
- Refinements (since initial run)
- Wall sizes
- Outputs
V2.0 - New Envelope (Heating only)
- Inputs
- New Envelop walls, floors, roof
- Windows: U = .27
- Heating = Gas radiant heaters
- No Cooling
- Ventilation??? (How does Energy-10 simulate the ventilation of space?)
- Default Lighting and Other Energy assuming office and warehouse uses
- Zone 1 = Historic Building (8,721sf)
- Zone 2 = Addition (2,720sf)
- Refinements (since initial run)
- Wall sizes
- WWF% using Laura's numbers
V2.5 - New Envelope (Heating only - New Furnance)
- Inputs
- New Envelope walls, floors, roof
- Windows: U = .27
- Heating = Gas furnace upgrade (Eliminates any distortion due to existing heaters)
- No Cooling
- Default Lighting and Other Energy assuming office and warehouse uses
- Zone 1 = Historic Building (8,721sf)
- Zone 2 = Addition (2,720sf)
- Refinements (since initial run)
- Wall sizes
- WWF% using Laura's numbers
- Refinements (since initial run)
V2.7 - New Envelope (Analysis of Cooling)
- Inputs
- New Envelope walls, floors, roof
- Windows: U = .27
- Heating = Gas furnace / DX Cooling
- Default Lighting and Other Energy assuming office and warehouse uses
- Zone 1 = Historic Building (8,721sf)
- Zone 2 = Addition (2,720sf)
- Analysis
- Examine Solar Gain - use window shading to block solar gain
- Examine heat from lighting - eliminate internal lighting
- Examine heat from other internal sources - eliminate other sources
- Try running simulation under "Free Run" which is the building without HVAC, ventilation, internal gains
- Refinements
- Wall sizes
- WWF% using Laura's numbers
- Outputs
V3.0 - New Envelope (Heating and Cooling)
- Inputs
- New Envelop walls, floors, roof
- Windows: U = .27
- Heating = Gas furnace upgrade (Eliminates any distortion due to existing heaters)
- Cooling = Standard AC unit
- Ventilation??? (How does Energy-10 simulate the ventilation of space?)
- Default lighting and other uses assuming office and warehouse uses
- Zone 1 = Historic Building (8,721sf)
- Zone 2 = Addition (2,720sf)
- Refinements (since initial run)
- Wall sizes
- WWF% using Laura's numbers
- Outputs
V4.0 Lighting
- Inputs
- New Envelop walls, floors, roof
- Windows: U = .27 (Finalize window specification)
- Heating = Gas furnace upgrade (Eliminates any distortion due to existing heaters)
- Cooling = Standard AC unit
- Lighting
- Include Skylight for Solatube
- Zone 1 = Historic Building (8,721sf)
- Zone 2 = Addition (2,720sf)
- Refinements (since initial run)
- Outputs